| Compendium of test facilities |
 |
Environmental Testing for electrical and electronic items |
 |
Ingress of protection provided by enclosures |
 |
Load test |
 |
Temperature rise test |
| Accreditation and Recognition |
Si’Tarc Electrical Engineering Division is accredited by NABL (National Accreditation Board for testing and calibration Laboratories, Department of Science and Technology, India in accordance with standard ISO / IEC 17025:2005 for its facilities in the field of ELECTRICAL TESTING (Certificate No. T-0078)
Si’Tarc Electrical Engineering Division is recognized by Bureau of Indian Standards as OUTSIDE
RECOGNIZED LAB (Code No 6104904).
Si’Tarc Electrical Engineering Division test facilities are fully utilized by the reputed agencies UL India Private Ltd, TUV Rheinland (India) Pvt Ltd, INTERTEK Testing Services India Pvt Ltd for testing of electrical products as per international standards, CE marking requirements, safety tests etc |
| Electrical Motor Testing |
 |
A.C. ELECTRIC MOTORS |
| |
|
| |
|
| |
|
| |
|
 |
D.C. ELECTRIC MOTORS |
 |
SMALL UNIVERSAL MOTORS |
| |
|
| |
NABL ACCREDITATION for ELECTRICAL MOTOR TESTING |
| |
| S.No. |
Standard No. |
Specification |
| 1. |
IS : 325-1996 |
Three Phase induction motors |
| 2. |
IS : 996-1979 |
Single phase small AC and universal electric motors |
| 3. |
IS : 2972(Part1)-1979 |
Textile motors |
| 4. |
IS : 7538-1996 |
Three phase squirrel cage induction motors for centrifugal pumps for agricultural applications |
| 5. |
IS : 8034-2002 |
Submersible pumpsets |
| 6. |
IS : 8472-1998 |
Pumps -regenerative for cold water |
| 7. |
IS : 9079-2002 |
Electric monoset pumps for clear cold water for agricultural and water supply purposes |
| 8. |
IS : 9283-1995 |
Motors for submersible pumpsets |
| 9. |
IS : 12225-1997 |
Centrifugal jet pump |
| 10. |
IS : 12615- 2004 |
Energy efficient induction motors –Three Phase squirrel cage |
| 11. |
IS :14220-1994 |
Open well submersible pumpsets |
| 12. |
IS :14582-1998 |
Single phase small a.c. electric motors for centrifugal pumps for agricultural applications |
|
| |
|
|
| |
 |
 |
Eddy current + Magnetic powder (Tandem) Dynamometer up to 50kW |
|
|
 |
 |
| |
 |
 |
Hydraulic Dynamometer Up to 20kW |
|
|
 |
|
 |
| |
 |
 |
IP 5x Test apparatus
Dust test Chamber
Dust test as per IEC pub 947-1(1988)
Size: 1.5 x1.5 x 1.5 mts. |
|
|
 |
 |
| |
 |
 |
IP 6x Test apparatus |
|
|
 |
 |
| |
 |
 |
Power rating : 45 kW |
 |
Operating frequency : 0 to 400HZ |
 |
Output voltage : 0 to 480V |
 |
Output current : 91A |
 |
Output power : 69 KVA |
 |
Running condition :Forward/reverse |
|
|
 |
 |
|
 |
 |
Power rating : 18.5 kW |
 |
Operating frequency : 0 to 400HZ |
 |
Output voltage : 0 to 480V |
 |
Output current : 39A |
 |
Output power : 30 KVA |
 |
Running condition :Forward/reverse |
|
|
 |
 |
|
 |
 |
60 Hz power source Single Phase,240V,100A. |
|
|
 |
 |
|
 |
 |
60 Hz power source
Three phase,415V,120A. |
|
|
 |
 |
|
 |
 |
Voltage up to 600V AC |
 |
Current up to 100A AC |
 |
Power up to 50kW |
 |
Analog and digital instruments |
|
|
 |
 |
|
|
 |
Load manager
0-750V,300A,30kW. |
|
|
 |
 |
|
 |
 |
Temperature up to 1500°C
Type K, Type J, Type R |
|
|
 |