SCIENTIFIC AND INDUSTRIAL TESTING AND RESEARCH CENTRE
Promoted by SIEMA & CODISSIA and Supported by COINDIA
 
 
 
ELECTRICAL ENGINEERING DIVISION
Motor Testing Materials Testing Others NABL
Electrical Engineering division is having the facilities to cater major electrical motor testing and electrical material testing.
 
Regulated power supply ,Single phase and Three Phase
Uninterrupted power supply
Separate 50 Hz and 60 Hz electrical power source
Eddy current and Magnetic powder Dynamometer
DC Drives
Precision power measurement
Variable frequency drives
Electric Oven, Humidity Chamber, Cold chamber ,Dust Chamber and Salt Spray chamber
 
Compendium of test facilities
Environmental Testing for electrical and electronic items
Ingress of protection provided by enclosures
Load test
Temperature rise test
Accreditation and Recognition
Si’Tarc Electrical Engineering Division is accredited by NABL (National Accreditation Board for testing and calibration Laboratories, Department of Science and Technology, India in accordance with standard ISO / IEC 17025:2005 for its facilities in the field of ELECTRICAL TESTING (Certificate No. T-0078)

Si’Tarc Electrical Engineering Division is recognized by Bureau of Indian Standards as OUTSIDE RECOGNIZED LAB (Code No 6104904).

Si’Tarc Electrical Engineering Division test facilities are fully utilized by the reputed agencies UL India Private Ltd, TUV Rheinland (India) Pvt Ltd, INTERTEK Testing Services India Pvt Ltd for testing of electrical products as per international standards, CE marking requirements, safety tests etc
Electrical Motor Testing
A.C. ELECTRIC MOTORS
 
Voltage up to 600 Volts
 
Frequency 50Hz - 60Hz
 
Output 60HP (In-house)
 
Output 800HP ( On site)
D.C. ELECTRIC MOTORS
SMALL UNIVERSAL MOTORS
   
  NABL ACCREDITATION  for ELECTRICAL MOTOR TESTING
 
S.No. Standard No. Specification
1.
IS : 325-1996
Three Phase induction motors
2.
IS : 996-1979
Single phase small AC and universal electric motors
3.
IS : 2972(Part1)-1979
Textile motors
4.
IS : 7538-1996
Three phase squirrel cage induction motors for centrifugal pumps for agricultural applications
5.
IS : 8034-2002
Submersible pumpsets
6.
IS : 8472-1998
Pumps -regenerative for cold water
7.
IS : 9079-2002
Electric monoset pumps for clear cold water for agricultural and water supply purposes
8.
IS : 9283-1995
Motors for submersible pumpsets
9.
IS : 12225-1997
Centrifugal jet pump
10.
IS : 12615- 2004
Energy efficient induction motors –Three Phase squirrel cage
11.
IS :14220-1994
Open well submersible pumpsets
12.
IS :14582-1998
Single phase small a.c. electric motors for centrifugal pumps for agricultural applications
   
Dynamometer up to 50kW
Eddy current + Magnetic powder (Tandem) Dynamometer up to 50kW
Dynamometer Up to 20kW
Hydraulic Dynamometer Up to 20kW
IP 5x Test apparatus
IP 5x Test apparatus Dust test Chamber Dust test as per IEC pub 947-1(1988) Size: 1.5 x1.5 x 1.5 mts.
IP 6x Test apparatus
IP 6x Test apparatus
Variable frequency drive 01
Power rating : 45 kW
Operating frequency : 0 to 400HZ
Output voltage : 0 to 480V
Output current : 91A
Output power : 69 KVA
Running condition :Forward/reverse
Variable frequency drive 02
Power rating : 18.5 kW
Operating frequency : 0 to 400HZ
Output voltage : 0 to 480V
Output current : 39A
Output power : 30 KVA
Running condition :Forward/reverse
60 Hz power source single Phase
60 Hz power source Single Phase,240V,100A.
60 Hz power source three Phase
60 Hz power source Three phase,415V,120A.
Electrical measuring instruments
Voltage up to 600V AC
Current up to 100A AC
Power up to 50kW
Analog and digital instruments
Load Manager
Load manager 0-750V,300A,30kW.
Data Logger DA 100
Temperature up to 1500°C Type K, Type J, Type R